We use cookies to ensure that we give you the best experience on our website. I am still getting the error code. } Then, disconnect the thermistor and reconnect it. What does E05 mean on a Pentair pool heater? They should be able to tell you the correct dipswitch settings for your model so you can correct it yourself. Just turn on a hot water faucet and let the water run for several minutes. There are a range of potential causes to this error. Smith reserves the right to deny reimbursement if, upon investigation, any such condition is identified. Now, you should be able to understand how these error codes work and what they mean. CODE: 51, 55, 510, 551, Six timesPROBLEM: Abnormal gas solenoid valve. Press down the gas control knob all the way in while depressing the igniter button continuously. Ao smith water heaters troubleshooting 2022 (Guide) - House Tipper Revision 3 includes updated troubleshooting for error codes 4 and 6 and technical bulletins, Manual will be automatically added to "My Manuals", Error Code 3 - Pressure Switch Circuit Remains Closed, Error Code 4 - Pressure Switch Circuit Remains Open, Error Code 7,8,9 - Internal Control Failures, Error Code 10 - Flame Sensed out of Sequence, Error Code 11 - High Temperature Cutoff (Eco) Activated, Error Code 12 - Temperature Adjust Buttons Stuck Closed, Error Code 13 - Temperature Probe Open of Shorted, Error Code 14 - Resistor Wire Open or Shorted, Error Code 15 - Resistor Wire Resistance out of Tolerance, Technical Bulletin - Ignition and Flame Failure A-022-04 & S-021-04 Combined, Air Pressure Switch Circuit - Residential Power Vent/Power Direct Vent, Vent Termination Restrictor Usage for 40,000 Btu Power Vent Models, TB-A028-06 - A. O. Smith - FVIR Intelli-Vent Troubleshooting Chart, Normal Operating Sequence - Pressure Switch Circuit, Air Pressure Switch Circuit: Residential Power-Vent & Power-Direct-Vent Water Heaters, Air Pressure Switch Circuit: Cyclone Water Heater. Check out advanced features for eco-friendly and cost-effective water heating. 2023 Virtual Campus Workshop Schedule Tour our upgraded studio and training facilities The LED status light flashes 0 times or it doesnt come on due to two reasons. Leave a comment in the box below if you have any questions about the Pentair pool heater. Finally, turn the power back to the unit and it will clear the error code. Built in dry fire protection will not allow the water heater to be turned on unless the tank is full of water, eliminating accidentally burning out the upper element. Your AO Smith Water Heater will make a beep once it detects a problem to notify you that something is going wrong with the unit. Fixing the error as soon as it appears is important for the performance and longevity of the pool heater. How to troubleshoot Rinnai water heaters successfully using Rinnai error codes guide. Turn the valve back on and set the pressure to the proper temperature. Check if there are any foreign particles or grease on the gas burner and fan motor. Put everything back into its place and turn the electricity on. The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. Very simple. FIX: Check if the condensate drain is installed on the vent collar of the heater. I recommend you turn the unit off and relight the pilot. BFC Cyclone Twister II Adjust the valves on the main line to set the water pressure at the right level. And then, use the wrench to secure the thermistor properly. If it's shorted out, unplug the machine . FIX: Check if the remote controller is the right type, also connections between the water heater and remote. A.O. Smith Water Heater Troubleshooting | Appliance Helpers This error code is closely related to the error code 11 (111) as it is a sign that your water heater is losing its flame. Continue with Recommended Cookies. FIX: Is the water heater set for the right elevation? A list of Takagi error codes for easy troubleshooting of Takagi tankless water heaters. You also have the option to opt-out of these cookies. . A.O. (57 reviews) Model: E6-50R45D-TTP Lowe's Item #: 2483230. If there is air in the waterline, your water heater may throw this erratic code. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Problem: Miscommunication in an Easy-Link system. Save my name, email, and website in this browser for the next time I comment. To view or adjust our assumptions of the most common factors that impact this products performance using National Averages, please view the
Visually inspect the thermistor connections. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. It will be best to consult with a certified professional or the technical support team. Check the thermistor connections. Already you know how to sort out the reasons behind the code and solve your Pentair heater error code E05. Malfunctioning Control Board 4. Start with turning off the gas control valve to the off position. Its important to note that the error codes we will be addressing in this guide are found on the 110, 510, 310, 240, 240 and 540 AO Smith tankless water heater models. Changing the gas control valve is not as difficult as you assume. And this tutorial will help in replacing the thermocouple on the AO Smith Water Heater: Secondly, inspect the wire connectors for loose. Ask a customer care specialist However, sometimes the provided manuals and instruction guides are not very clear and if you need help addressing some error codes that are popping up on your AO Smiths tankless water heater, then we have got you covered. To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. d. Igniter activates. Replace the control board. Summary of Contents for A.O. Troubleshooting John Wood tankless water heaters. If you dont know how to replace the sensor, call a professional for the replacement. Jenn-Air JGS8750ADB Control Panel Burning Hot! So, keep reading. CODE: 70, 701, One timePROBLEM: Problem with the computer board. Get a free estimate online from top local home service pros in your area. This cookie is set by GDPR Cookie Consent plugin. When the heating element shorts out, it will cause a short circuit, which will allow it to continue heating, causing the water to become too hot. We and our partners use cookies to Store and/or access information on a device. The thin flow of water is typically a result of scaled-up pipes or improper water pressure. However, there is no need to be panicked because they have the solution for this circumstance. how to fix the Pentair heater error codes problem, Rheem Tankless Water Heater Maintenance [Why+ How To Do], Rheem Tankless Water Heater Code 61 [Why+ How To Fix], Rheem Tankless Water Heater Code 14 [Why+ How To Fix], Rheem Tankless Water Heater Code 99 [Why+ How To Fix], Rheem Tankless Water Heater Code 76 [Why+ How To Fix]. CODE: 10 (101), Five timesPROBLEM: Warning for the "991" error code. 4.6. If you continue to use this site we will assume that you are happy with it.. All rights reserved. Than ks anyway Appliance Technician: Chester Just ignore the pop-up call request. Eccotemp Protection Plans are available for purchase within 60 days of your water heater purchase. How do I reset my A.O. 13 February 2021; Non class; 0 Comments Solution: Check for the soot on the AFR rod, wire connection, and breakage. If you see any scale buildup on your motor drive, you will need to clean it away with hydrochloric acid and water mixture (wear appropriate protection gear while handling this mixture). Copyright 2020 - 2022 | All rights reserved. Fortunately, I broke down how you can replace the thermistor correctly in this section: Ao Smith Electric Water Heater Error Code E10-E13. If they come loose, tighten them up. Smith Water Heater Error Codes. Revision 2 includes updated troubleshooting information for error codes 3, 4, and 6. Then, watch this tutorial and follow the steps to get the temperature sensor replaced: If you observe the status light of your water heater flashes 7 times consecutively with a three-second pause, understand the gas valve is at fault. Shop by Popular AO Smith Water Heater Models. Trouble codes on the AO Smith Water Heater mean your water heater is not working properly. Then, find the source of the water leak. Of course, you are always open to reaching out to a professional if you fail to clear the error messages. Solution: Check for connection and breakage of wires, burn marks on the computer board, and power supply to the unit. CODE: 651, Four timesPROBLEM: Flow adjustment valve fault. WaterHeater HUB 2021 - All Rights Reserved. No problems with the new one, plus it was much cheaper and lowes gave me a credit for the old one, not just a straight replacement, so I ended up with a lowes gift card for the difference. Too High Temperature 2. Join our exclusive 2,500+ email list to get tailored advice, product roundups, and be the first to see our new content. If this error code has appeared on your AO Smith tankless water heaters LED screen, then this is a sign that you have set the incorrect settings for the dipswitch. I initially had to replace the lower element due to limescale. Then, use a flathead screwdriver to remove the nuts that hold the upper access panel in its place. Status light blinking once every 3 seconds but I dont see a flame in the window. In this case, the pilot light will be lit but the thermopile fails to generate the required output voltage. You can either left-click on the link to open the manual in a new tab or right-click and save a copy directly on your computer. This error code pops up whenever there is a fault with the fan motor of your tankless water heater. From https://www.justanswer.com/ythiJustAnswer Customer from San Antonio, TX: AO Smith 50 gallon electric water heater giving error code e55 for water leak d. Reasons Why There Is Water Leak Inside Refrigerator, Why Does My Air Conditioner Keep Freezing Up? Manuals - A. O. Smith ME Solution: Check the wire connection for looseness or breakage. If this doesnt bring any luck to you, the best bait is to call a professional for further assistance. AO Smith ES12-50R55DV (50 gallon) electric hot water tank. event : evt, The board replacement kit includes replacement yellow and blue wires with new connectors. Possibly a short somewhere, check all your wires for frayed or cut insulation on them shorting out. It will be convenient for the homeowners who are handyman at the same time. Error code 441 (LED flashes two times) Problem: Flow sensor. This prevents proper connectivity between the system and the sensor, causing the heater to shut down and display the E05 error code. A. O. Smith. Here are The Facts! Hi, I have an AO Smith GCVL 40 300 natural gas with a Honeywell valve. This error code is another thermistor failure but this time, it is referring to the mixing or mix thermistor. Products: Water Heaters . Solution: Before AO Smith tankless water heater troubleshooting, test the hi-limit switch and confirm it is working fine and the wire connections are not loose and broken. Problem: Problem with the computer board. listeners: [], Error Code 61, 611, Four times Problem: Fan motor fault. What does ECC code mean A.O. A.O. Smith University | An Education in Hotwater A.O. The showers in homes built after 1992 typically have a flow rate of 2.1 Gallons Per Minute. Solution: Check if there is a loose or breakage in the wire connection or debris on the thermistor. If there are any burn marks on the computer board then this is a sign that your water heaters computer board is overheating and cutting out. Manage Settings Turn the gas control valve to the off position in the first place. To solve this error, you will need to carry out the same checks and treatments in the above error. He said it appeared the thin wires for the smart module had burned out from the plastic connector. Before inspecting for leaks, turn the unit off. Verify Warranty - Enterprise Portal - Hotwater I have tested the power at the thermostat and the elements with a multi meter and they all check out fine. Related Troubleshooting Pages:A.O. Nevertheless, it will mean that people have to learn more about Ao Smith Water Heater Codes for understanding the error and the solution. Thank you. Gas Tank; Electric Tank; Hybrid Tank; Expansion Tanks; Tankless . CODE: 99, 991, Five timesPROBLEM: Improper gas combustion. Our comprehensive A.O. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! On the other hand, your AO Smith Water Heater goes through problems if the status light flashes more than 1 times followed by a three-second pause. Legal Disclosure:Lildutchuncle.com provides and shares information on plumbing, heating & air quality, home improvement, and other DIY projects. Solution: Check for the proper settings on the computer board. CODE: 31, 311, Two timesPROBLEM: Outlet thermistor failure. Clean away any dirt or debris and check the quality of the connection wires. You should be able to find the settings in your water heaters manual, but if you are stuck, contact the support at AO Smith. Keep opening the hot faucets until all the air gets expelled out of the water heater. Now, turn the electric power on to your water heater. Residential & Commercial Water Heating Systems | A. O. Smith Never Descale Again. CODE: 12, 121, Three timesPROBLEM: Flame loss. Turn the gas supply on and check for leaks by spraying soap solution on the connections. I checked all the wires and didn't find any problems, frayed insulation, etc. Manual for 1500 - 3000 models. Shorted Heating Elements 5. scald in a matter of minutes. compare. You can see the flash code once you relight the pilot light. Smith INTELLI-VENT Page 1 INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters Printed in the USA - 0605 Part No. FIX: Check for connection/breakage of wires, corrosion or frozen connectors, fan motor covered with the dust, burn marks on the computer board. Mix the soap and water in a spray bottle. Save my name, email, and website in this browser for the next time I comment. View more. See the symptoms of How to fix water hammer problem in pipes. Just like with the previous thermistor failure errors, you should follow the same process to solve it. Our product specs, warranty sheets, installation guides, and user manuals are online. var intYear = dteNow.getFullYear();
How To Fix: First off, turn the gas control knob to the off position. Smith water heater? Does the status light of your AO Smith Water Heater remain solid red? Less things to go wrong. Yesterday morning my water heater was beeping but no error code. First off, turn the gas control knob to the off position. Secondly, you must replace the gas control valve if the pilot valve gets stuck in an open position. A faulty code E06 on your AO Smith Water Heater stands for too hot water temperature. Otherwise, the status light wont blink. Fireplacehubs.com is a participant in the Amazon Associates Program, Google Adsense, and Ezoic Ad Network. When the temperature of the stack flue rises above a certain degree, this error message will show up on your heater. GCVL40-200 GCVL40-201 GNR40100 GNR50100 GPS-75 GPVH40100. Understanding Noritz error codes and troubleshooting Noritz water heaters. FIX: Check is the Hi-limit switch properly functioning that there is no loose or broken wire connections, no soot on the flame rod or damaged computer board. View All Tankless Models with X3 Learn About Tankless with X3 Scale Prevention Technology Disconnect the main water line and turn off the heater before properly cleaning the pipes. Generally, the water heater will display this faulty code if the outlet thermistor (TH-4) remains open. Though resetting the unit will fix and clear the error code, you must figure out whats overheating the water. Here are some error codes which can be learned. These cookies track visitors across websites and collect information to provide customized ads. COPYRIGHT 2023. Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. The error code may also be flashing three times. Tank Guard gives you advanced tank protectionextends the life of your water heater. The following steps will help you change the thermistor: Start with turning off the electric power to your water heater. Ensure you shut off the electric supply to your water heater. We also use third-party cookies that help us analyze and understand how you use this website. Solution: Check if the remote controller is of the right type, also connections between the water heater and remote. Clean your AFR rod of any soot, and check for any damage or loose connections to see if you need to find a replacement. Related Pages:pool heater repair nearby, water heater repair cost, home pool heater service, water heater fix near me, pool heater installation near me. It usually means that there is a problem with the bypass valve. Fixing the error codes immediately is a must in the Pentair pool heater to avoid further problems to happen. As a result, you can now easily diagnose your water heater that will save you both time and money. This cookie is set by GDPR Cookie Consent plugin. For example, if the status light blinks 2 times, there is an issue with the thermopile voltage output. Regarding this, you need to replace the thermocouple or the wire connectors. Smith Water Heater Age Determination - reader comment: (May 11, 2012) AO Smith employee said: To tell the age of any AO Smith water is the first 4 numbers. You should consult with a licensed professional and check local permit requirements before starting any project. However, a damaged thermal regulator often prevents the water from flowing out, causing it to be trapped in the exchanger. It sounds like the main control is malfunctioning, what's the complete model number of this water heater? Any other models may have different codes for different issues. When the temperature sensor senses the water temperature is excessively hot, the status light will flash 4 times. smith gas water heater installation user and service manual (102 pages) Water Heater A.O.Smith GPSX-50L Owner's Manual. I unplugged the electronic panel, and the unit functions for a few hours when I turn off the breaker, wait several minutes then turn it on again. The Pentair error code E05 indicates an open stack flue sensor. CODE: 441, Two timesPROBLEM: Problem with the flow sensor. Ever. We don't tend to provide any plumbing advice or any advice that should come from a certified professional. The gas pressure to the Pentair pool heater often gets obstructed due to clogged gas pipes, incorrect pressure settings, and turned off gas valves. Ignition failure is not an uncommon issue with water heaters and boilers, but its also highly recommended that you solve this issue by calling a technician to your home. Basically, both 2-chamber and 4-chamber models will pop up with those error codes. Now, press the red button to reset the unit successfully. Repair or replace the sensor properly if there are any issues.if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[120,600],'fireplacehubs_com-leader-4','ezslot_11',113,'0','0'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-leader-4-0');if(typeof ez_ad_units!='undefined'){ez_ad_units.push([[120,600],'fireplacehubs_com-leader-4','ezslot_12',113,'0','1'])};__ez_fad_position('div-gpt-ad-fireplacehubs_com-leader-4-0_1');.leader-4-multi-113{border:none!important;display:block!important;float:none!important;line-height:0;margin-bottom:15px!important;margin-left:auto!important;margin-right:auto!important;margin-top:15px!important;max-width:100%!important;min-height:600px;padding:0;text-align:center!important}. Problem: Problem with the air-fuel ratio rod - AFR. The thermostat(s) on this water heater have been factory set to 120F to reduce the risk of scald injury. Solution: Check if the condensate drain is installed on the vent collar of the heater. Before doing so, dont forget to check the wiring attached to the control board. This morning it started beeping again but still no error message. A.O. Smith - Troubleshooting help - DoItYourself.com Community Forums For example, a model 510 will display the numerical code on the 7-Seg LED on the computer board, while the 110 and 310 models only a blinking red LED that can flash one time or more. JavaScript is disabled. ECS40200 FPCR50260E GCNH30100 GCNH50100 GCV30 GCV40. This is exactly where the thermistor is located, depending on models: Once you locate the thermistor, detach the thermistor wires from the control board. Pentair Heater E05 Error Code [Reasons + Solutions] - FireplaceHubs Is the surrounding air contaminated? Years of experience in the HVAC field have taught him many lessons, not the least of which is that the value of quality and knowledge far exceeds any promised initial savings. Its very simple to reset your AO Smith Electric Water Heater by following the below instructions: ECC stands for Electro-chemical compression. A guide to troubleshooting water heaters with the listed error codes below is useful for DIY homeowners, but our recommendation is always to get help from a qualified technician. Remove the access panel and fold away the insulation. FIX: Check is there a loose or breakage in wire connection or debris on the thermistor. Try our Product Selector Tool to find the right models for your needs-for both heating and treating your home's water. But then sometime later it will start to heat the water and the green light will begin flashing rapidly. Open up the control panel and check the wires connected to the stack flue sensor. It will clear the error code. CODE: 711, One timePROBLEM: Gas solenoid valve drive circuit failure. It functions just like an outlet thermistor, but is found on your inlet pipes instead of your outlet pipes. These features are included with all Signature 500 Series water heaters. If the resistance of this part goes out of range, you must replace it.